DWSD Customer Service Phone Number 313-267-8000.  
    DWSD 24-hour Emergency Service Phone Number 313-267-7401

Search DWSD.ORG

DWSD.ORG, the official website of the Detroit Water and Sewerage Department.
DWSD Standard Design Drawings

These files require AutoCad 2000 or higher or can also be opened with DWG TrueView available free, here.





AutoCAD 2000


Acrobat


Description
ALL* All AutoCAD 2000 drawings for this Division
01014-01 Drain Guard
01014-02 Erosion Control, Silt Fence
01014-03 Soil Erosion Control Blankets
01014-04 Ditch Sediment Trap
01014-05 Temporary Inlet Sediment Filter
01014-06 Soil Erosion and Sedimentation Control, Temporary Facilities
01014-07 Soil Erosion and Sedimentation Control, Maintenance Notes
01014-08 Soil Erosion and Sedimentation Control, General Notes
01014-09 Soil Erosion and Sedimentation Control, Measures (From 1-5)
01014-10 Soil Erosion and Sedimentation Control, Measures (From 6-10)
01014-11 Soil Erosion and Sedimentation Control, Measures (From 11-15)
01014-12 Soil Erosion and Sedimentation Control, Measures (From 16-20)
01014-13 Soil Erosion and Sedimentation Control, Measures (From 21-24)
01014-14 Soil Erosion and Sedimentation Control, Measures (From 25-28)
01014-15 Soil Erosion and Sedimentation Control, Measures (From 29-32)
01014-16 Soil Erosion and Sedimentation Control, Measures (From 33-36)
01014-17 Soil Erosion and Sedimentation Control, Measures (From 37-40)
   
back to top Division   1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17






AutoCAD 2000


Acrobat


Description
ALL* All AutoCAD 2000 drawings for this Division
02530-01 Connection, Saddle, to Lateral Sewer
02530-02 Wye, Connection and Extension
02530-03 Bedding, Pipe, Sanitary Sewer (1 of 2)
02530-04 Bedding, Pipe, Sanitary Sewer (2 of 2)
02600-01 Manhole, Precast
02600-02 Manhole, Precast Bottoms and Water Cushions
02600-03 Manhole, Sizing Chart
02600-04 Manhole, Assembly (1 of 2)
02600-05 Manhole, Assembly (2 of 2)
02600-06 Manhole, Sizing Chart with KOR-N-SEAL Connectors
02600-07 Manhole, Cover with Frame
02600-08 Manhole, Step, Copolymer Polyproylene Plastic (1 of 2)
02600-09 Manhole, Step, Copolymer Polyproylene Plastic (2 of 2)
02600-10 Manhole, Exterior Drop
02600-11 Manhole, Interior Drop
02600-12 Manhole, Sump with Flexible Joint
02600-13 Manhole, Sump with Boot and Stainless Steel Band
02600-14 Manhole, Over Existing Sewer
02620-01 Box, 2-1/2 Inch, Service, Telescoping (1 of 3)
02620-02 Box, 2-1/2 Inch, Service, Telescoping (2 of 3)
02620-03 Box, 2-1/2 Inch, Service, Telescoping (3 of 3)
02620-04 Box, 5-1/4 Inch Roadway, Telescoping
02620-05 Casing Pipe Section for Watermain
02620-06 Connection, New Main to Existing Main Using Tapping Valve
02620-07 Connection, Service, Residential
02620-08 Encasement, Typical Water Distribution Pipe Bend
02620-09 Encasement, Valve and Well Assembly in Concrete (1 of 2)
02620-10 Encasement, Valve and Well Assembly in Concrete (2 of 2)
02620-11 Encasement, Water Distribution Pipe in Concrete
02620-12 Gate Well, Precast (1 of 2)
02620-13 Gate Well, Precast (2 of 2)
02620-14 Hydrant, 6 Inch, Installation Offset
02620-15 Hydrant, 6 Inch, Installation Straight Away
02620-16 Marker, Appurtenance,Transmission Main
02620-17 Meter Box, 1 Inch
02620-18 Thrust Block, Horizontal Bend (AWWA Sizing)
02620-19 Thrust Block, Plugs, Caps, and Tees (AWWA Sizing) (1 of 2)
02620-20 Thrust Block, Plugs, Caps, and Tees (AWWA Sizing) (2 of 2)
02620-21 Thrust Block, Horizontal Bend (Traditional DWSD Sizing)
02620-22 Thrust Block and Tees (Traditional DWSD Sizing)
02620-23 Thrust Block Plugs and Tees (Traditional DWSD Sizing)
02620-24 Thrust Block, Vertical Bend (AWWA Sizing) (1 of 2)
02620-25 Thrust Block, Vertical Bend (AWWA Sizing) (2 of 2)
02620-26 Thrust Block, Vertical Bend (Traditional DWSD Sizing) (1 of 2)
02620-27 Thrust Block, Vertical Bend (Traditional DWSD Sizing) (2 of 2)
02620-28 Valve, Blow-Off, 4 Inch, Temporary
02620-29 Valve, Gate, Cradle Support, Concrete
02620-30 Valve, Holder, 1-1/2 Inch Service
02630-01 Grate, Flat with Frame
02630-02 Grate, Flat with Frame Bolt Down
02630-03 Throttled Catch Basin Cover
02820-01 Fence, Gates (1 of 2)
02820-02 Fence, Gates (2 of 2)
02820-03 Fence, Truss Connections
02820-04 Fence, #9 Ga. Wire and Barb Arm Connection
02820-05 Fence, Typical Rail Coupling
02820-06 Fence, Chain Link and #9 Ga. Wire Connection
02900-01 Planting, Coniferious Tree
02900-02 Planting, Deciduous Tree
02900-03 Planting, Shrub
   
back to top Division    1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17






AutoCAD 2000


Acrobat


Description
ALL* All AutoCAD 2000 drawings for this Division
03200-01 Reinforcement, Openings to 4’-0” (1 of 2)
03200-02 Reinforcement, Openings to 4’-0” (2 of 2)
03200-03 Repair of Concrete and Steel Reinforcement (1 of 4)
03200-04 Repair of Concrete and Steel Reinforcement (2 of 4)
03200-05 Repair of Concrete and Steel Reinforcement (3 of 4)
03200-06 Repair of Concrete and Steel Reinforcement (4 of 4)
03250-01 Equipment Base, in Existing Concrete
03800-01 Duration of Protection for Concrete Placed in Cold Weather
   
back to top Division    1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17






AutoCAD 2000


Acrobat


Description
ALL* All AutoCAD 2000 drawings for this Division
04811-01 Typical Reinforcement at Wall Opening
04811-02 Typical Cavity Wall Control Joint
04811-03 Exterior Load Bearing Wall with Interior Non-Load Bearing Wall
04811-04 Exterior Load Bearing Wall with Interior Load Bearing Wall
04811-05 Anchor Detail at Concrete Wall
04811-06 General, Wall Section
04811-07 General, Cavity Wall Construction
04811-08 General, Brick Veneer Wall Section
04811-09 General, Reinforced Block Wall
   
back to top Division    1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17






AutoCAD 2000


Acrobat


Description
ALL* All AutoCAD 2000 drawings for this Division
05500-01 Bollard, Industrial
05500-02 Entrance Ladder
05510-01 Stair, Grating Section with Typical Base
05520-01 Railing
05550-01 Anchor Bolts
05630-01 Hatch, Access, Cover
05630-02 Grading Hatch
05630-03 Hatch, Entrance, Cover
05630-04 Pump and Motor Access Cover
   
back to top Division    1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17






AutoCAD 2000


Acrobat


Description
ALL* All AutoCAD 2000 drawings for this Division
06550-01 Fiberglass Reinforced Plastic Guardrail
06550-02 Aluminum Ladder (1 of 2)
06550-03 Aluminum Ladder (1 of 2)
   
back to top Division    1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17






AutoCAD 2000


Acrobat


Description
ALL* All AutoCAD 2000 drawings for this Division
07100-01 General Foundation Wall and Floor Slab Waterproofing
07100-02 Waterproofing For Conduit Through Wall
07500-01 Typical Flashing for Lintel and Base
   
back to top Division    1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17






AutoCAD 2000


Acrobat


Description
ALL* All AutoCAD 2000 drawings for this Division
08100-01 General Foundation Wall and Floor Slab Waterproofing
   
back to top Division    1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17






AutoCAD 2000


Acrobat


Description
ALL* All AutoCAD 2000 drawings for this Division
09000-01 Finish Schedule
09260-01 Gypsum Shaft Wall System (1 of 2)
09260-02 Gypsum Shaft Wall System (2 of 2)
09300-01 Ceramic Tile Installation
   
back to top Division    1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17






Not Applicable




Not Applicable




Not Applicable

back to top Division    1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17






AutoCAD 2000


Acrobat


Description
ALL* All AutoCAD 2000 drawings for this Division
13400-01 Meter Vault, Standard Notes
13400-02 Meter Vault, Concrete (1 of 2)
13400-03 Meter Vault, Concrete (2 of 2)
13400-04 Meter Vault, Metal, Small (1 of 2)
13400-05 Meter Vault, Metal, Small (2 of 2)
13400-06 Meter Vault, Metal, Large (1 of 2)
13400-07 Meter Vault, Metal, Large (2 of 2)
13400-08 Industrial Meter Setting, 1½ ” and 2”, In Basement
13400-09 Industrial Meter Setting, 3” to 12”, In Basement
13400-10 Meter Vault, Sump Pump Piping
13400-11 Meter Vault, Exterior Piping
13400-12 Meter Vault, Replacement Notes
   
back to top Division    1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17






Not Applicable






AutoCAD 2000


Acrobat


Description
15601-S01* 15061-S01 Schedule 15061-S01, Ductile Iron Pipe Schedule
15062-S01* 15062-S01 Schedule 15062-S01, Steel Pipe Schedule
15063-S01* 15063-S01 Schedule 15063-S01, Light Wall Steel Pipe Schedule
15091-S01* 15091-S01 Schedule 15091-S01, Miscellaneous Ball Valves Schedule
(1 of 3 to 3 of 3)
15092-S01* 15092-S01 Schedule 15092-S01, Industrial Butterfly Valves Schedule
(1 of 3 to 3 of 3)
15094-S01* 15094-S01 Schedule 15094-S01, Backflow Preventer Schedule
15095-S01* 15095-S01 Schedule 15095-S01, Solenoid Valve Schedule
15099-S01* 15099-S01 Schedule 15099-S01, Pressure Reducing Valves Schedule (1 of 2 to 2 of 2)
15100-S01* 15100-S01 Schedule 15100-S01, Yard Hydrants Schedule
15101-S01* 15101-S01 Schedule 15101-S01, AWWA Butterfly Valves Schedule (1 of 2 to 2 of 2)
15102-S01* 15102-S01 Schedule 15102-S01, Eccentric Plug Valves Schedule (1 of 3 to 3 of 3)
15103-S01* 15103-S01 Schedule 15103-S01, AWWA Ball Valves Schedule (1 of 4 to 4 of 4)
15104-S01* 15104-S01 Schedule 15104-S01, Resilient-Seated Gate Valves Schedule
15105-S01* 15105-S01 Schedule 15105-S01, Double Disc Gate Valves Schedule (1 of 2 to 2 of 2)
15106-S01* 15106-S01 Schedule 15106-S01, Cone Valves Schedule Schedule (1 of 4 to 4 of 4)
15108-S01* 15108-S01 Schedule 15108-S01, Air Release and Combination Air Valve Schedule
15140(A)* 15140(A) Hangers and Supports(1 of 2)
15140(B)* 15140(B) Hangers and Supports(2 of 2)
   
back to top Division    1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17






AutoCAD 2000


Acrobat


Description
16050-01* 16050-01 600 Volt, Single conductor Lighting Cable (600-1-PVC-THHN-THWN)
16050-02* 16050-02 600 Volt, Single Conductor Lighting/Power Cable (600-1-XLP-NONE-XHHW)
16050-03* 16050-03 600 Volt, Single Conductor Lighting/Power Cable (600-1-PVC-THHN-THWN)
16050-04* 16050-04 600 Volt, Single Pair, Shielded Instrument Cable (600-SINGLE-PAIR-SH-INSTR)
16050-05* 16050-05 600 Volt, Single Triad, Shielded Instrument Cable (600-SINGLE-TRIAD-SH-INSTR)
16050-06* 16050-06 600 Volt, Multiple Pair and/or Triad, Shielded Instrument Cable (600-MULTI-PAIRS-TRIADS-SH-INSTR)
16050-07* 16050-07 600 Volt, Multiconductor 14 AWG (2.5 mm2) Control Cable (600-MULTI-THHN-THWN)
16050-08* 16050-08 600 Volt, Multiconductor 12 AWG (4 mm2) Control Cable (600-MULTI-THHN-THWN)
16050-09* 16050-09 Voltage Test After Installation: DC Test Voltage – 35 Kv, Duration of Test – 15 Minutes, 8000 Volt, Single Conductor Power Cable, 100 Percent Insulation Level (8000-1-EPR-PVC-SH)
16050-10* 16050-10 Voltage Test After Installation: DC Test Voltage – 65 Kv, Duration of Test – 15 Minutes, 15,000 Volt, Single Conductor Power Cable, 133 Percent Insulation Level (15-1-EPR-PVC-SH)
16050-11* 16050-11 600 Volt, 3 Conductor With Ground Power Tray Cable (600-3-XLP-PVC-TC)
16050-12* 16050-12 600 Volt, Single Conductor Power Tray Cable (600-1-VW-1-NONE-XHHC-TC)
16050-13* 16050-13 600 Volt, Single Conductor Power/Lighting Cable (600-1-XLP-NONE-RHH-RHW-USE)
16050-14* 16050-14 600 Volt, Type MC Metal Clad Lighting Cable (Metal Clad THHN)
16050-15* 16050-15 Cable Tray Data Form
16500-01* 16500-01 Lighting Fixture Schedule
   
back to top Division    1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17






AutoCAD 2000


Acrobat


Description
17500-01* 17500-01 Instrumentation General Requirements
   
back to top Division    1  | 2  | 3  | 4  | 5  | 6  | 7  | 8  | 9  | 10  | 11  | 12  | 13  | 14  | 15  | 16  | 17